Target Vision Security Systems
Target Vision Security Systems
Kalyan Vihar, Priyadarshani Vihar, Delhi
GST No. 07AAIFT8702E1Z6
Send E-mail
Call 0804873299084% Response Rate

Bosch Fire Alarm Systems


Wholesale Trader of a wide range of products which include fap-440 analog photoelectric detectors, fah-440 analog heat detector, fah-425-t bosch addressable heat detector, fap-425-ot bosch addressble multi detector, bosch fpa-1000-v2 addressable fire panel and dx connexion fire alarm panel.

Get Best Quote

Approx. Rs 2,543 / Piece Get Latest Price

Product Brochure
Product Details:
Minimum Order Quantity20 Piece
BrandBosch
Voltage24 VDC to 41 VDC
Relative Humidity95% (non-condensing)
Protection CategoryIP 42
Alarm5 mA
Standby0.17 mA
Installation Temperature+32 deg F to +100 deg F (0 deg C to +38 deg C)

The FAP???440 Analog Detectors are open-area smoke detectors of which some models are enhanced with heat or heat and CO sensors. These detectors work with the FPA???1000 Analog Addressable Fire Panels. Use these detectors with the FAA???440 bases to provide general life safety and property protection.

Features:
  • Smoke threshold is adjustable and automatically compensated
  • Rotary switch addressing
  • Flexible work modes determined by the control panel
  • Selectable base locking mechanism prevents malicious removal of the detector
  • Multi???criteria or multi???sensor technology reduces false alarms

 

Functions:

Address Range:

  • The FAP???440 Analog Detectors have a valid address range from 1 to 254 which is set by rotary switches on the back of each detector.

 

Indicator LED:

  • The detector head has a multi???color LED to indicate status. To verify power to the detector and functioning communication of the analog addressable loop, the LED indicator flashes green when operating normally (polling). Through panel parameter setting, it is possible to turn on or off operation of the polling indicator. In the event of an alarm condition, the detector LED will always show a steady red light.

 

Modular Construction:

  • These detectors are part of a two???piece modular design for detector assemblies. An FAP???440 Analog Detector attaches to an FAA???440 Family base. The base’s security locking tab prevents any unauthorized detector removal from the base.

 

Multi???sensor detector:

  • The multi???sensor detector contains a photoelectric smoke sensor and a heat sensor. Either sensor can detect a fire and activate an alarm signal. The smoke threshold is adjustable (see Sensitivity Calibration and Compensation below) while the heat sensor’s threshold is set at 135°F.

 

Multi-criteria detector:

  • The multi???criteria detector also contains smoke and heat sensors that work independently of each other, but in conjunction with the CO sensor. In this model, an alarm signal will be activated by either one or both of the sensors only if the CO level is also exceeded.

 

Programming:

  • Local programming is carried out at the panel keypad or by computer through a Web browser. Remote programming is carried out through a Web browser.

 

Sensitivity Calibration and Compensation:

  • The sensitivity of the smoke sensor is programmable with 12 levels from which to choose. Throughout its normal life cycle, the smoke detector monitors itself against its factory calibrated level and periodically compensates itself to keep the sensitivity at it programmed level. When the detector is excessively contaminated, this condition will be annunciated at the control panel.

 

The following wire gauges were tested and approved:

Wire GaugeMaximum length
18 AWG (ISO 0.75 mm )4000 ft (1200 m)
16 AWG (ISO 1.5 mm 2 )6225 ft (1900 m)
14 AWG (ISO 2.5 mm 2 )7200 ft (2200 m)
12 AWG (ISO 4 mm 2 )9850 ft (3000 m)

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 1,958 / Piece Get Latest Price

Product Brochure
Product Details:
Minimum Order Quantity40 Piece
Model NumberFAH-440
BrandBosch
Protection CategoryIP 42
Operating Voltage24 VDC to 41 VDC
Alarm5 mA
Standby0.17 mA
Relative Humidity95% (non-condensing)
Storage Temperature-13 deg F to +176 deg F (-25 deg C to +80 deg C)
Airflow4000 ft/min (20 m/s) maximum

The FAH‐440 Analog Heat Detector is an open-area fire detector that works with the FPA‐1000 Analog Addressable Fire Panels. Use it with the FAA‐440 family of bases in indoor dry environments with high ambient temperatures where smoke detectors might not be suitable because of steam or fumes; such as kitchens, boiler rooms, or drying rooms.

Features:
  • Selectable Fixed Temperature threshold
  • Rate-of-Rise feature can be switched on or off
  • Selectable base locking mechanism prevents malicious removal of the detector

Functions:
Address Range:
  • The detector has a valid address range from 1 to 254 which is set by rotary switches on the back of the detector.

Indicator LED:
  • The detector head has a multi‐color LED to indicate status. To verify power to the detector and functioning communication of the analog addressable loop, the LED indicator flashes green when operating normally (polling). Through panel parameter setting, it ispossible to turn on or off operation of the polling indicator. In the event of an alarm condition, the detector LED will always show a steady red light.

Modular Construction:
  • The detector is part of a two‐piece modular design for detector assemblies. A detector attaches to a base in the FAA‐440 Analog Standard Base or Analog Isolator Base family. The base’s security locking tab prevents any unauthorized detector removal from the base.

Programming:
  • Local programming is carried out at the panel keypad or by computer through a Web browser. Remote programming is carried out through a Web browser.

Selectable Threshold Setting:
  • The detector has an alarm threshold temperature range of +135°F to +194°F (+57°C to +90°C) with 17 possible settings. The rate-of-rise feature can be switched on or off.

 

Mounting Considerations:
Detectors are typically mounted on the ceiling. However, if detectors are mounted on a wall, they must be at least 4 in. (10.2 cm), but no more than 12 in. (30.5 cm), below the ceiling. When other devices containing magnets or producing magnetic fields (for example, loudspeakers) are present in the area, the base must be at least 1 ft (30 cm) from these devices to prevent unwanted activation of the test switch.


Remote Indicator:

  • If a remote indicator is used in the circuit, it must be no more than 10 ft (3 m) from the base.

The following products are compatible with the FAH‐440 Analog Heat Detector:
Category Product ID Product Description
Fire Panels FPA‐1000 Series Analog Addressable Fire Panels
Fire Panel Accessories FPE‐1000‐SLC Signaling Line Circuit Plug‐in Module
Detector Bases FAA‐440‐B4 4‐inch Analog Standard Base

FAA‐440‐B6 6‐inch Analog Standard Base

FAA-440-B4- ISO 4‐inch Analog Isolator Base

FAA-440-B6- ISO 6‐inch Analog Isolator Base


Additional Information:
  • Item Code: FAH-440

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

Product Brochure
Product Details:
TypeHeat Detector
Model Name/NumberFAH-425-T
VoltageOperating voltage 15 V DC to 33 V DC Current consumption < 0.55 mA
WeightApprox. 85 g / Approx. 130 g
Response SensitivityThermal maximum part > 54 DegreeC / >69 DegreeC -
MaterialPlastic, ABS (Novodur)

Analog addressable heat detector with one thermal sensor, manually and automatically addressable. Order number FAH-425-T-R

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

Product Brochure
Product Details:
BrandBosch
TypeMULTI DETECTOR
Model Name/NumberFAP-425-OT
Body MaterialPlastic
ColorWhite
Voltage15 V DC to 33 V DC
Alarm BandAlarm output Per data word by two-wire signal line
Current Capacity A< 0.55 mA

The FAP425-DOTC-R, FAP425-DOT-R, FAP425-OT-R, and FAP425-OT versions are planned in accordance with the guidelines for optical detectors if operated as optical detectors or as combined optical/thermal detectors (see DIN VDE 0833 Part 2 and VDS 2095) • If occasional deactivation of the optical unit (scattered light sensor) is required, planning must be based on the guidelines for heat detectors (see DIN VDE 0833 Part 2 and VDS 2095) • When planning fire barriers according to DIBt, note that the heat detector (FAH-425-T-R) must be configured in accordance with class A1R.

Yes! I am Interested


Get Best Quote

Approx. Rs 1.39 Lakh / Unit Get Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Unit
ModelFPA-1000-V2
Voltage24 VDC
Weight18.1 lb (8.32 kg)
Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
ColorRed
BrandBosch
Size14.5 in. x 4.3 in. x 22.7 in.
Protection ClassIP 30
Storage Temperature+14 deg F to +131 deg F (-10 deg C to +55 deg C)

The FPA1000V2 UL Analog Addressable Fire Panel is an advanced analog control panel for small to medium facilities in commercial or public building applications. The FPA???1000???UL combines complete built-in Fire Alarm Control Panel (FACP) equipment such as Notification Appliance Circuits (NACs), Signaling Line Circuits (SLCs), relays, power supply, Digital Alarm Communicator Transmitter (DACT), and Ethernet connection with expandability using the option bus or plug???in boards. The two integrated NACs can be expanded with remote addressable NAC power boosters
and programmed with specific activation patterns.

Features:
  • Support for up to 508 points on two analog addressable loops
  • Built???in Ethernet connector for web???browser based programming and ConettixIP Alarm-over-IP communication
  • Carbon Monoxide Detector (gas) support meets NFPA 720 (2009) requirements for visual and audible annunciation
  • Auto???Learn mode for easy provisioning
  • On???line help and off???line programming capability provide simple configuration and service.

 

Trouble conditions. The built???in keypad can be used for total system control and programming even when wearing fireman gloves. In addition, a large 4???line by 20???character alphanumeric LCD display shows programmed device point information. Four keys enable Drill, Reset, Silence, and Acknowledge functions.

 

The FPA???1000???UL enables various programming approaches:

  • Two different phone or IP numbers
  • Different dialing types for PSTN (pulse only, tone and pulse, or tone only)
  • Individual PSTN line supervision (audible and visual trouble signal in the case of a transmission path failure)
  • Selectable options for Report Steering Groups
  • Programmable acknowledge wait time for each IP reporting Conettix account (15 sec up to 255 sec)
  • Test call frequency individually programmable for each account (4, 12, 24 hour, 7 and 28 day intervals, standard frequency 24 hour)

 

Notification Appliance Circuits (NACs):

  • Two Class A Style Z or Class B Style Y NACs provide up to 4 A of 24 V power (non-synchronized: 2.5 A per NAC; synchronized: 2.75 A NAC 1 + NAC 2 in total) to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 4, Temporal Code 3, and steady, puls- ing, and synchronized protocol output for Wheelock, Gentex, and System Sensor notification appliances.

 

Signaling Line Circuits (SLCs):

  • The FPA???1000???UL Fire Panel uses the patented DCP Digital Communication Protocol to communicate with each of the analog addressable devices located on the SLCs. This fast and reliable protocol allows the use of standard non???twisted, non???shielded wiring for the SLCs. The FPA???1000???UL supports two Class B, Style 4 or one Class A, Style 6 or 7 per SLC.

 

Mounting Considerations:

  • The cabinet can be either semi-flush (requires optional FPM???1000???SFMK Semi-flush Mounting Kit) or surface mounted.
  • Depending on the configuration and the battery selection, the FPA???1000???UL can be quite heavy. When attaching the enclosure to a surface, use mounting hardware (not supplied) capable of supporting this weight, and reinforce the wall as necessary.

 

Wiring Considerations:

  • The length of wire allowed between the control panel and the last device on a wiring run depends on the current drawn on that wiring run. Reducing the number of devices on a wiring run allows the individual runs to be longer.


Additional Information:
  • Item Code: FPA1000UL

Yes! I am Interested


Get Best Quote

Approx. Rs 1.39 Lakh / Unit Get Latest Price

Product Details:
System ComponentsFire Alarm Control Panel
Dimension260 x 390 x 147mm
Voltage230 V AC
Circuits2 Sounder Circuits
ApplicationFire Detection
Operating Temperature0 to +40 deg C

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

Product Brochure
Product Details:
Power28 v dc (15-33VDC)
BrandBosch
Body Materialpc,abs(ul94 v-2 )
Consumption0.5-6.55 mA
Dimensions Wxhxd40*99.5 mm
Operated ByDc at temp - 20 degree C to 60 degree C
Voltage28 v dc (15-33 VDC)
Weight67gm

The LSN Strobe can be used with the FNM-420-A-BS / FNM-420U-A-BS Base Sounders or the MSS 400 / MSS 401 LSN Detector Base Sounders providing a combination of visual and acoustic signaling. Mounted on the MS 400 Detector Base, the FNS-420-R can be used as a strobe without acoustic signaling. Both applications can easily be integrated into an existing Local SecurityNetwork (LSN).

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

Product Brochure
Product Details:
Brandbosch
System ComponentsFire Alarm Control Panel
Model Name/NumberFPA-5000
Height Feet638mm

the modular configuration, the innovative FPA???5000 Modular Fire Panel easily adapts to local circumstances and regulations. Due to the different functional modules, country-specific characteristics are accommodated in the connection just as quickly as the respective alarm handling.

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

Product Brochure
Product Details:
BrandBOSCH
Model Name/NumberFLM-420-O1I1-E
DimensionsFLM-420-O1I1-E Approx. 50 mm x 22 mm ( x H) FLM-420-O1I1-D incl. adapter Approx. 110 x 110 x 48 mm

  • General Description

    • The FLM???420???O1I1 Output-input Interface Modules are fitted with one output to control external devices and with one monitored input
    • with 1 open collector output and 1 monitored input, in-built version

     

     

     



  • Features

    • Semi-conductor output electrically isolated from LSN loop and short-circuit proof
    • Max. switchable current per output 700 mA
    • Individually selectable input monitoring functions (EOL or contact)
    • Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators




  • Data Sheet

    Download

    FLM-420-O1I1-E Output-input interface module in-built

     

     

  • Specification

    LSN  
    LSN input voltage 15 V DC to 33 V DC
    Max. current consumption from LSN 1.9 mA
    Output  
    Max. switchable voltage of semi-conductor output 30 V DC
    Max. switchable output current 700 mA (depending on power supply)
    External power supply 5 V DC to 30 V DC
    Input  
    Line monitoring with EOL  
    EOL resistor Nominal 3.9 k???
    Overall line resistance RΣ with RΣ = RL/1 + RL/2 + REOL Standby: 1500 ??? to 6000 ??? Short circuit: < 800 ??? Line interruption: > 12.000 ???
    Contact monitoring  
    Max. current strength (current pulse) 8 mA
    Minimum activation time of the input 3.2 s

     

     


Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

Product Brochure
Product Details:
operating vtgDC 12 v - 30 v
Maximum ConsumptionStandby 140 milli amp@ 24v dc alaram 230 milli Amp - 24 vtg
Resistance18 ohm
Dimension280*340*87 mm
WieghtCA,3kg
Operating Tempminus -5 to 50 degree celsius
Storage Tempminus -20 degree to 70 degree celsius

The Remote Keypad is a convenient solution for theremote operation of the FPA 1200 Fire Panel, theFPA 5000 Modular Fire Panel or a complete network.The design of the user interface is identical with that of the FPA 1200 and FPA 5000 Panel Controllers andthere fore enables an intuitive and quick operation.In a network of FPA 5000 fire panels, up to 32 Panel Controllers, Remote Keypads and OPC server can beinter connected The Remote Keypad is a convenient solution for theremote operation of the FPA 1200 Fire Panel, theFPA 5000 Modular Fire Panel or a complete network.The design of the user interface is identical with thatof the FPA 1200 and FPA 5000 Panel Controllers andtherefore enables an intuitive and quick operation.In a network of FPA 5000 fire panels, up to 32 PanelControllers, Remote Keypads and OPC server can beinterconnected

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

Product Brochure
Product Details:
BrandBOSCH
Materialplastic,ABS
Voltageoperating voltage 15v dc to 33 vdc
Weightapprox 80g
Size/Dimension099.5 x 52mm

Yes! I am Interested


 



Door Frame Metal Detector



Corporate Brochure




 

 

Send SMS
Shashank Agarwal  (CEO)
Target Vision Security Systems
11, Bhama Shah Marg Part 1, Opposite Guru Harkishan Public School
Kalyan Vihar, Priyadarshani Vihar, Delhi - 110009 , India
Send E-mail
Share Us:
X